كل الرسائل

سؤال: How it work i have 4 pieces but all is not working 😭 pleas explain me

السؤال بواسطة lobnahaseen على 2021-11-05 01:28:23

sometimebuyer There are 4 switched line connections , it is all explained on the sticker in the main unit

2021-11-06 12:16:34 مساعدة (0)
عرض
أجابات (1)

سؤال: How do people stick it on the wall?

السؤال بواسطة den525 على 2021-10-03 12:46:06

sometimebuyer Use the double sided sticker that comes with it.

2021-10-03 03:33:30 مساعدة (0)
عرض
أجابات (6)

سؤال: What is the range of voltage adjustment?

السؤال بواسطة info على 2021-01-18 11:50:18

sometimebuyer There is no voltage adjustment

2021-01-20 05:20:01 مساعدة (0)
عرض
أجابات (1)

سؤال: Can I power a CCTV camera that requires 12vDC 2A 15W from this power supply? Thank you

السؤال بواسطة Japie على 2021-01-02 03:53:02

sometimebuyer Your use is well under the maximum power available as your camera is actually supposed to draw 1.2A (15W) if the specifications are correct. But that seems a significant power draw for the camera so is probably a maximum.

2021-01-03 06:04:04 مساعدة (1)
عرض
أجابات (11)

sometimebuyer An emergency switch shoul be on the lin in connection. So other neutral gos to the NVR then from the NVE to the load The line connects first to the emergency switch then from the emergency switch to the NVR then from the NVR to the load. An earth condition should not go through any switches to the machine being controlled. If you do not understand these instructions DO NOT do the connections yourself get an electrician to do them. If you don’t understand enough you can kill your self & others.

2020-08-11 06:29:54 مساعدة (0)
عرض
أجابات (2)

sometimebuyer It uses a 5v supply so you can use a power-bank Or mains, it also has a 3032 to keep current time and alarm but not show it.

2020-07-11 10:13:26 مساعدة (1)
عرض
أجابات (2)

سؤال: Is it harmful to electronic devices (TV, PC monitor, etc) in the room?

السؤال بواسطة kostastzanas على 2020-03-06 04:46:19

sometimebuyer Only in the same way as strong sunlight would affect them

2020-03-06 04:55:23 مساعدة (0)
عرض
أجابات (1)

سؤال: is it suitable for wires used heaters

السؤال بواسطة GAMES TECHNOLOGY GURU على 2018-09-09 09:40:51

sometimebuyer I think you are talking about a high voltage load, so no

2020-02-25 11:06:46 مساعدة (0)
عرض
أجابات (1)

سؤال: Will this work on UK voltage?

السؤال بواسطة shahzad على 2020-02-25 10:35:26

sometimebuyer Yes, no problem

2020-02-25 11:05:02 مساعدة (0)
عرض
أجابات (1)

سؤال: check with you, 6" clamp only has a throat depth of 12mm ?

السؤال بواسطة Kong CK على 2020-01-13 09:30:50

sometimebuyer The thread diameter is 12mm the throat is 80mm

2020-01-24 11:10:45 مساعدة (0)
عرض
أجابات (3)